  • Ideal isar HE30 Boiler pressure — Digital Spy

    Dec 23, 2012 · In my case, the fix is just to re-inflate it (with air!): wait till water pressure is low (and the boiler is off!). Let out some more water by bleeding a radiator or from a drain cock until pressure is 0. Then use a tyre-pump (with gauge) on that valve, which will probably read 0. Inflate to about 0.7bar, and remove.Get Price

  • Glow-worm Boiler Problems, Repair Advice & How to Fix

    Low boiler pressure (108 or F22) Losing pressure: There could be a water leak in the system, the pressure relief valve needs replacing or the radiators have been bled recently Glow-worm boilers come with 2-7 years of warranty as standard but some models are eligible for up to 15 years of warranty through Glow-worm's club energy installers.Get Price

  • Boiler pressure keeps dropping ? What to check - Flexiheat

    Mar 14, 2019 · You should only refill your central heating system when the system has cooled down. You simply open the valves up, slowly and wait for the pressure gauge on the boiler to rise to 1.2 Bar to 1.5 Bar maximum (please consult you boiler manual for the recommended pressure that they stipulate).The process is then finished off by closing the valves, thus sealing the …Get Price

  • Ideal Logic Boiler Problems - Common Problems & Fixes

    3 Answers from MyBuilder Plumbers. MPH Gas services. Pontypridd • Member since 15 Nov 2018 • 97 jobs, positive feedback. 79153. Chances are that your prv is passing and you are losing your central heating water through it. I had a new combi boiler installed recently and the boiler is losing pressure. The installer is claiming there Get Price

  • Ideal mini 24 losing pressure fast | DIYnot Forums

    Sep 03, 2019 · Hi, I have an ideal mini 24 boiler that loses pressure almost instantly once filled. All our pipes are above the floor and i can detect no leaks, all valves are tight and no aparent leaks. When i bled the radiators upstairs they were quite low and the water seemed fizzy. The ones downstairs didnt take much bleeding and the water flowed as normal.Get Price

  • Why my Combi boiler is losing pressure - MyBuilder

    But boiler still losing pressure. A plumber has replaced the PRV and confirmed no water escaping from overflow pipe. Today we have isolated the boiler by turning the valves to separate it from the central heating system. When hot water was called for the pressure gauge rapidly drops by 0.5 bar then recovers a little when hot water is shut off Get Price

  • Boiler losing pressure overnight | Screwfix Community Forum

    Mar 18, 2021 · My boiler has been losing pressure overnight for the past 3 months. Boiler is Worcester Greenstar R28HE system with a Flomax hot water cylinder. Boiler is fine during the day when in use, I top it up to 1.5 bar, when heating and hot water is turned on the pressure stays more or less the same. When it is not in use overnight the pressure drops to 0.Get Price

  • Ideal Boiler FD Fault Code - Plumbing | Heating | Gas

    Unlike most common boiler problems, the Ideal FD fault code can sometimes be fixed on a DIY basis. The first thing you need to do is check that your boiler has pressure. There's a pressure gauge on the front of your boiler, which should be reading around 1.3 bar.Get Price

  • Ideal ISAR Boiler - Pressure rising above 3 bar & leakin

    Dec 12, 2011 · Country: Hi can anyone help me with a problem with my IDEAL ISAR HE30 boiler. When CH is on pressure on gauge rises to above 3 bar within 15mins & then leaks via PRV & out thru pipe outside, needing to refill to 1bar when cold. So far had 2 different engineers, 1st said faulty pressure gauge, then he said expansion vessel which he then changed.Get Price

  • How to top up the pressure on an Ideal Logic +30kw combi

    Hi, this is a video brought to you by 1st Gas Engineers Ltd. Customers are often asking us how to top up the pressure on their Ideal boilers and so we decideGet Price

  • Losing pressure on Ideal Icos | DIYnot Forums

    Sep 03, 2019 · Amelia1730. Pressure kept dropping on our Ideal Icos boiler (gone from every few weeks to weekly, now daily). Each morning the heating doesn't come on because it's below 1 on the gauge. I top up and we get heat until it drops again. Plumber finally had to re pressurise the expansion tank last week.Get Price

  • Why Is My Boiler Losing Pressure? | Boiler Tips | Ideal

    Ideal Logic Boiler Problems - Common Problems & FixesGet Price

  • Ideal Mini C28 losing pressure on Central Heating

    Mar 20, 2012 · Start date Mar 15, 2012; Tags boiler central heating expansion heating pressure vessel Copy link Copy link Discuss Ideal Mini C28 losing pressure on Central Heating in the Central Heating Forum area at PlumbersForums.net. Status Not open for further replies. 1; 2; Next. 1 of 2 Go to page. Go. Next Last. S. stget02gt. Mar 15, 2012 Get Price

  • USER GUIDE - Ideal Heating

    IDEAL 24 30 35 When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance 15 1 6 17 18 I 0 min preheat min preheat max mode reset off status burner max e TO START THE BOILER THE BOILER WILL NOT OPERATE IF THE PRESSURE HAS REDUCED TO LESS THAN 0.3 BAR UNDER THIS CONDITION Get Price

  • Boiler keeps losing pressure: 7 possible reasons why - DIY

    Jan 25, 2018 · Boiler keeps losing pressure – what pressure should my boiler be? While the correct amount of pressure may vary depending on model and manufacturer, most combi boiler systems require a pressure of 1 to 1.5 bar when cold. Water expands when it's heated, and so the pressure rises when the boiler is on.Get Price

  • Boiler keeps losing pressure | PlumbersForums.net

    Jun 24, 2021 · 3b. Isolate the boiler flow and return pipes at their valves under the boiler. 3c. Do not run the boiler for a period of 24 hours. 3d. If the pressure still drops then the fault is within the boiler. 3e. Open the valves, and wait a further 24 hours. If the pressure then drops, the fault is within the system. 4.Get Price

  • Ideal Logic combi 35 loosing pressure on gauge ( isolated

    Ironically, low pressure can be caused by having the pressure too high. Your system should have a pressure relief valve to keep it safe – the water outlet is usually located outside the home, behind where the boiler is located. If your pressure is a little too high when the system is cool, turning it on will make it even higher, and it will Get Price

  • My ideal logic 24 combi boiler keeps losing pressure.i

    Jan 09, 2018 · My ideal logic 24 combi boiler keeps losing pressure.i have to keep opening the water taps to start it working again. - Answered by a verified Plumber We use cookies to give you the best possible experience on our website.Get Price

  • Ideal Logic combi 35 boiler pressure drops to zero

    Feb 02, 2019 · 4. When CH is switched off pressure starts falling down and settles. Following the re-pressurising of boiler after the very first use of CH, the pressure settles to about 1.3. Then onwards at each subsequent use of CH pressure goes to 1.8 while on and settles to a lesser vale when off and cool. (For example 1.2, 1.0 etc)Get Price

  • BOILER KEEPS LOSING PRESSURE - WHY AND HOW TO FIX

    Does the pressure in your Combi boiler or heating system boiler keep dropping? Here's how to fix it! We'll show you why it happens, and how to fix it. We'll Get Price

  • New Ideal vogue leaking and dropping pressure overnight

    Sep 03, 2019 · Been working fine until last Sunday. Woke up cold, pressure gauge at zero, dashed round the house checking rad valves but all ok. Re-pressurised system and boiler fired up ok and all seemed ok. BUT, noticed a dripping from the left rear corner of the boiler and damp insulation. I put a pot underneath and phone Ideal.Get Price

  • My Boiler is Leaking Water - What Should I Do? | Ideal Heating

    In most boilers, the pressure should be between 1 and 1.5 bar when the central heating is off. When it's on, it will go up slightly, but it should still be around this range. If it's way above this level (say, 2 bar or higher), this could be the cause. Boilers have pressure relief valves to protect them from high water pressure.Get Price

  • How to top up the pressure on your Ideal Boiler - YouTube

    Jan 15, 2019 · Watch this video for advice from Technical Trainer Vince Johnson on how to safely top up the pressure on your Ideal Boiler.Get Price

  • Rapid Pressure Loss in Boiler | Screwfix Community Forum

    Nov 12, 2014 · Looking for advice, my combi boiler lost pressure on sunday so I topped it up to 1.5 bar, this gradually dropped down to less than 1bar through the night but then when topped up again to 1.5 bar it dropped to 0 within 30 mins, I've topped it up around 4 times now and it's back down to 0 within half an hour. The copper outlet pipe outside is dry Get Price

  • Boiler Keeps Losing Pressure, Ideal Heat Exchanger Leak

    Boiler losing pressure when heating off. Our boiler is constantly losing pressure (ie. dropping below 1 bar, often to zero), but only usually when the heating is turned OFF. The pressure relief valve outside is wet/dripping (although I don't know if it only drips when the heating is off, or whether it's dripping all the time).Get Price

  • Ideal Boiler Problems, Repair Advice & How to Fix

    Ideal boiler pressure should sit around the 1.5 bar mark, you can check this by taking a look at the built-in pressure gauge. Over time, an Ideal boiler will very gradually reduce pressure but if there's a sudden drop in pressure it's likely that it will be down to a leak in the system or the radiators having recently been bled.Get Price

  • Ideal Combi boiler keeps loosing pressure. | Screwfix

    Oct 10, 2020 · Mike's right, check the prv discharge pipe outside (pipe on far left when looking at the boiler) to see if water has been flowing. Next turn the boiler off, turn off flow and return and disconnect the white condensate pipe with a tub under if in morning tub has water in then the heat exchanger has been leaking. RobJamesHeating, Oct 9, 2020.Get Price

  • new boiler losing pressure - Singletrack Magazine Forum

    went for a new ideal boiler with 10yr guarantee (in our house that we rent out to my daughter). since its been installed the system keeps losing pressure.Get Price

  • What Should I Do if My Boiler is Losing Pressure? Quick Fixes

    Reason 1 for your boiler losing pressure – Water leaks in the system. Depending on the brand of your boiler, the pressure in your system should be between 1 and 1.5 bars. If the pressure levels are below this your system won't fire up. The majority of the time if your boiler is losing pressure it will be down to a leak somewhere in the system.Get Price

  • Why does my boiler keep losing pressure? | Love Your Boiler

    May 24, 2016 · Why does my boiler keep losing pressure? If we had £1 for everytime we'd heard the question, "why does my boiler keep losing pressure?", we'd have at least £247 by now!. The fact is, this is a common problem with all poorly maintained sealed systems. Firstly, if we explain what a sealed system is, you'll find it much easier to understand why your boiler keeps losing …Get Price

  • Boiler Keeps Losing Pressure, Ideal Heat Exchanger Leak

    Apr 09, 2020 · If your boiler is continuously losing pressure and you have to keep topping it up to keep it working and you can not find the leak. Then this video may be fGet Price

  • Does your combi boiler pressure keep dropping ? Does it

    If your Combination boiler keeps losing pressure here is what to do, to fix that problem, Al shows you how. Got your own plumbing or heating problem? Ask Al Get Price

  • Potterton Promax combi HE Plus Pressure Dropping

    Oct 01, 2019 · The reason that the pressure is dropping is because the expansion vessel inside the boiler has failed or simply needs re-pressurising. If your system pressure is rising above 3 bar towards 4 bar, the pressure release valve will operate discharging into the pipe outside that you have put the bag over, allowing the system pressure to drop.Get Price

  • Boiler losing pressure - MyBuilder

    The central heating system is about 15 years old and the boiler is 6 years old and recently serviced. Any advice would be greatly appreciated. Many thanks. Ashton. ashtoncross. 3 3 Answers from MyBuilder Gas Engineers. Best Answer. Bennett's Plumbing. Wellington I had a new combi boiler installed recently and the boiler is losing pressure Get Price

  • Boiler Pressure - Free Heating Advice

    Oct 21, 2021 · With the heating system cold, the pressure should be between 1 and 1½ bar. With the heating system turned off, the only pressure in the boiler and radiators was the pressure from the the weight of water above that point (the static pressure). The higher the header tank was above the radiators, boiler and pipework, the higher the static pressure.Get Price

  • My ideal logic Combi 35 boiler loosing pressure

    Nov 13, 2021 · 2,348. Nov 13, 2021. #2. Switch off the CH & the HW off and the power to the boiler. Can you just top it up and note the pressure, then shut the CH Flow and CH Return isolating valves, leave it for a hour or so (or enough time in your estimation to cause a pressure drop "normally") and note the pressure.Get Price

  • How do I reset my ideal logic 15 boiler?

    High boiler pressure isn't dangerous, even if it's showing as three bar on the pressure gauge. In most cases, the boiler will turn itself off if the pressure goes about a certain level and a working PRV should successfully control the pressure, preventing it from getting too high .Get Price

  • new boiler losing pressure - Singletrack Magazine Forum

    went for a new ideal boiler with 10yr guarantee (in our house that we rent out to my daughter). since its been installed the system keeps losing pressure.Get Price

  • New Ideal vogue leaking and dropping pressure overnight

    Sep 03, 2019 · Been working fine until last Sunday. Woke up cold, pressure gauge at zero, dashed round the house checking rad valves but all ok. Re-pressurised system and boiler fired up ok and all seemed ok. BUT, noticed a dripping from the left rear corner of the boiler and damp insulation. I put a pot underneath and phone Ideal.Get Price

  • Ideal 15 boiler losing pressure - MyBuilder

    Hi. I have an Ideal 15 boiler. It showed a fault this evening of F1 meaning low pressure and shows just above 1 bar. I read the guide to increase pressure to 1.5 which should make it work again however I needed a filling loop.Get Price

  • Boiler pressure loss through condensate pipe? | DIYnot Forums

    Mar 10, 2020 · I'm looking for some advice with a pressure loss issue that has been driving me mad for a while! It's on my vaillant 637 ecotec boiler, which is losing about 0.5-0.7 bar of pressure per day at present. Just to be clear - I am not a professional so will not be attempting to do any work on the system myself.Get Price

  • Boiler losing pressure when heating off - MyBuilder

    Ideal Logic Boiler Problems - Common Problems & FixesGet Price

  • Why Is My Boiler Losing Pressure Q&A - My CMS

    The cause of the boiler losing pressure can be due to wear and tear or an underlying fault on either the boiler or the central heating system. In most cases, we find that the central heating has been checked for air in the radiators or work for example a radiator has been taken of the wall. If the boiler is about 15 to 25-years old then there Get Price

  • Boiler Losing Pressure, No Leaks - MyBuilder

    Ideal Logic Boiler Problems - Common Problems & FixesGet Price

  • How To Top Up The Pressure On Your Ideal Boiler - YouTube

    Learn more at:.aquashieldplumbing.co.uk/This short video shows you how to add re-pressurise your Ideal Logic gas boiler.Get Price

  • Boiler Losing Pressure? Here's Why and What You Need to

    Jun 04, 2021 · The [DIY] Fix If Your Boiler Pressure Keeps Dropping. 99% of the time, your boiler keeps losing pressure due to leaks in the boiler itself, or somewhere in the heating system. Before spending 100s of pounds on a repair engineer, there is a DIY fix that may sort out your boiler's pressure — it comes in the form of the Fernox F4 leak sealant.Get Price

  • Ideal mini 24 losing pressure fast | DIYnot Forums

    Sep 03, 2019 · Hi, I have an ideal mini 24 boiler that loses pressure almost instantly once filled. All our pipes are above the floor and i can detect no leaks, all valves are tight and no aparent leaks. When i bled the radiators upstairs they were quite low and the water seemed fizzy. The ones downstairs didnt take much bleeding and the water flowed as normal.Get Price

  • Logic 24 losing pressure | DIYnot Forums

    Sep 03, 2019 · Lancashire. Country: Have an ideal logic 24 boiler, installed in 2011. over the past week its been losing pressure on a daily basis, upwards of a bar in pressure. there are no obvious leaks on the system, all rads bled and heat up fine and dhw works well. I would assume there would be an obvious leak losing that amount of pressure.Get Price

  • Boiler Water Pressure Low? The Reason Could Be Here

    How to check the water pressure on an ideal boiler. If you have the ideal Logic + or the ideal Vogue then you will see your pressure gauge right on the front of the user interface. It is the most left dial on the front of the Logic +boiler, and the small circular dial on the far right of …Get Price